- Производитель:
- Sigma-Aldrich
| Empirical Formula (Hill Notation): | CH4O |
| Linear Formula: | CH3OH |
| CAS Number: | 67-56-1 |
| Molecular Weight: | 32.04 |
| Beilstein/REAXYS Number: | 1098229 |
| EC Number: | 200-659-6 |
| MDL number: | MFCD00004595 |
| PubChem Substance ID: | 329755069 |
| NACRES: | NA.21 |
| Кат. номер |
| 34860JP-4X2.5L-R |
| 34860-5L-R |
| 34860-50L-P2-R |
| 34860-4X4L-R |
| 34860-4X2L-R |
| 34860-4X2.5L-R |
| 34860-4L-R |
| 34860-400L-P1-LS-R |
| 34860-2L-R |
| 34860-20L-P2-R |
| 34860-20L-N2-R |
| 34860-2.5L-R |
| 34860-1L-R |
| 34860-18L-P1-R |
| 34860-144X1L-R |
| 34860-10L-RC |
| 34860-100ML-R |
| 34860-200L-P2-LS-R |
| 34860-CR-200L-P2-R |
| 34860-200L-P24AB-R |
| 34860-200L-P1-LS-R |
| 34860-35L-P2-R |
| 34860JP-6X1L-R |
| 34860-100L-P2-R |
| 34860-199L-R |
| 34860-200L-P2-R |
| 34860-20L-P2-4A-R |
| 34860N-72X2.5L-R |
| 34860S-50L-R |
| 34860-6X1L-R |
| 34860-12X100ML-R |
| 34860-56L-R |
| 34860S-185L-R |
| 34860S-1000LRC |
| 34860S-1000L-RC |
| 34860S-1000L-R |
| 34860P-4X2.5L-R |
| 34860P-2.5L |
| 34860-7L-R |
| 34860-72X2.5L-R |
| 34860-45L-R |
| 34860-400L-R |
| 34860-35L-P2 |
| 34860-200L-R |
| 34860-2.5L-R-PC |
| 34860-18L-R |
| 34860-30L-R |
| 34860-IS-200LP2B-R |
| 34860-108X2.5L-R |
| 34860E-2.5L-R |
| 34860-10L-RC-R |
| 34860S-5BAR-200L |
| 34860E-4X2.5L-R |
Thermochemical conversion of methanol to C2-C10 hydrocarbons in the presence of shape-selective zeolites has been reported. Its oxidation on Ru-Pt catalyst system by ruthenium ad-atoms has been proposed.
Methanol (MeOH) has been used in the wholemount immunofluorescence studies of embryonic tissues.
It may be used in the following studies:
- Colony forming unit-fibroblast assay of bone marrow mononuclear cells.
- As solvent for the preparation of extracts of hyphae of Aspergillus for the estimation of gliotoxin by reversed phase-HPLC.
- Immunofluorescence studies.
- To compose the eluent for the ion-pair reverse-phase HPLC isolation of nucleotides and their decomposition products.
20, 50, 200 L in Pure-Pac™ 2
100 mL in glass bottle
18 L in Pure-Pac™ 1
View returnable container options.
Important notice
- The article number 34860-4X2.5L-R will be discontinued. Please order the single bottle 34860-2.5L-R which is physically identical with the same exact specifications.
- The article number 34860-6X1L-R will be discontinued. Please order the single bottle 34860-1L-R which is physically identical with the same exact specifications.
| Quality Level | 100 |
| vapor density | 1.11 (vs air) |
| vapor pressure | 410 mmHg ( 50 °C), 97.68 mmHg ( 20 °C) |
| assay | 99.9% |
| form | liquid |
| autoignition temp. | 725 °F |
| expl. lim. | 36 % |
| application(s) | HPLC: suitable, immunofluorescence: suitable |
| impurities | 0.0005% non-volatile matter, 1 ppb fluorescence (quinine) at 254 nm, 1 ppb fluorescence (quinine) at 365 nm, <0.03% water (Karl Fischer) |
| evapn. residue | <0.0005% |
| color | APHA: 10 |
| refractive index | n20/D 1.329 (lit.) |
| bp | 64.7 °C (lit.) |
| mp | 98 °C (lit.) |
| density | 0.791 g/mL at 25 °C (lit.) |
| neat | |
| UV absorption | : 205 nm Amax: 1.00, : 210 nm Amax: 0.60, : 220 nm Amax: 0.30, : 230 nm Amax: 0.20, : 235 nm Amax: 0.10, : 240 nm Amax: 0.10, : 260 nm Amax: 0.04, : 280 nm Amax: 0.01, : 400 nm Amax: 0.01 |
| Featured Industry | Food and Beverages |
| SMILES string | CO |
| InChI | 1S/CH4O/c1-2/h2H,1H3 |
| InChI key | OKKJLVBELUTLKV-UHFFFAOYSA-N |
| Pictograms | GHS02,GHS06,GHS08 |
| Signal Word | Danger |
| Hazard Statements | H225 - H301 + H311 + H331 - H370 |
| Precautionary Statements | P210 - P233 - P280 -
Пуско-наладка
Выполним распаковку, визуальную проверку, сборку и установку, запуск и настройку, проверку функциональности, проведем инструктаж персонала.
Техническое обслуживание
Проведем периодические регламентные работы: визуальный осмотр, очистка засоренных узлов и частей, замена расходных материалов и изношенных деталей, тестирование прибора, проверка показателей и измерение параметров, калибровка и настройка, обновление программного обеспечения.
IQ/OQ/PQ квалификация, валидация
Проведем монтажную (IQ), операционную (OQ) и эксплуатационную (PQ) квалификацию оборудования по протоколам производителя в полном соответствии с стандартами GMP/GLP.
Ремонт
Проведем диагностику в нашем сервисном центре или у Вас на предприятии, выявим причину поломки, устраним неисправность, проведем тестирование, настройку, калибровку отремонтированного оборудования.
Получите коммерческое предложение в течение 1 часаМенеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа
Анна Гловацкая
Менеджер по работе с клиентами
С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии
Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.
У большинства компаний срок ожидания составляет 10-12 недель.
Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.
Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.
В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.
Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей. ОтзывыВ числе наших клиентов организации
|