AOD 1 Decomposition system

AOD 1 Ñèñòåìà äëÿ ðàçëîæåíèÿ, IKA

Äàííûå àêòóàëüíû íà 11.04.2024.
Öåíà (åâðî): 15356,75 €
Öåíà (ðóá.): 1574715,42 ðóá.
Àðòèêóë DV-Expert: 6201431
Àðòèêóë ïðîèçâîäèòåëÿ: 0008801300 *
Ïðîèçâîäèòåëü: IKA
Ñðîê äåéñòâèÿ: 31.12.2024
Ïîñëåäíåå îáíîâëåíèå: 31.12.2023
Ïîëó÷èòü ïðåäëîæåíèå
Êîìïàíèÿ ÄÂ-Ýêñïåðò îñóùåñòâëÿåò ïîñòàâêè «0008801300 IKA» íàïðÿìóþ ñ çàâîäà-èçãîòîâèòåëÿ. Äëÿ òîãî, ÷òîáû ïîëó÷èòü êîììåð÷åñêîå ïðåäëîæåíèå íà «0008801300 IKA», ïîæàëóéñòà, îòïðàâüòå çàÿâêó â îòäåë ïðîäàæ.
AOD 1 Decomposition system
The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially inorganic samples under pressure in a closed system.
The system consists of:
AOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml)
In order to operate the decomposition system properly it is required to have a protective device in place in order to safely ignite the sample.
If such protective device is already in place, please add the accessory AOD 1.3 remote ignition head.
If no protective device is in place, our AOD 1.3 protective device could be chosen for example.
- Quantitative decomposition of all halogens, sulfur, as well as volatile metals, e.g. As and Hg
- Absorption of the combustion products in an aqueous medium
- Catalytic support of the oxidation process with auto-regenerating catalytic inner surface of the decomposition vessel
- Pressure vessel of high-grade stainless steel
- Decomposition temperature up to 1200 °C
- Max. operating pressure during decomposition 195 bar
- Decomposition time < 3 min
- The decomposition vessel can be changed over to use combustible crucibles C 14
- Control standards for Cl, S ( AOD 1.11)
- Introduction of the combustion gases into the absorption solution via venting station C 7030
Principle and function are based on the method of the combustion in the bomb calorimeter and validated according
DIN 51577-1
Other relevant standards are for example:
- DIN / EN 14582, determination characteristics of waste, halogen and sulfur content
- DIN 51527, Testing of solid samples, determination of chlorine content
  • Áðîøþðà


Ïîëó÷èòå êîììåð÷åñêîå ïðåäëîæåíèå â òå÷åíèå 1 ÷àñà

Ìåíåäæåð ïîäãîòîâèò êîììåð÷åñêîå ïðåäëîæåíèå è ïîçâîíèò, åñëè ïîíàäîáèòñÿ óòî÷íèòü äåòàëè âàøåãî çàêàçà

img
Àííà Ãëîâàöêàÿ Ìåíåäæåð ïî ðàáîòå ñ êëèåíòàìè
Ïîëó÷èòå êîììåð÷åñêîå ïðåäëîæåíèå â òå÷åíèå 1 ÷àñà
Êàê ê âàì îáðàùàòüñÿ?
Ââåäèòå òåëåôîí
Ââåäèòå email
Êîììåíòàðèé (åñëè åñòü)
Ïðèêðåïèòü ÒÇ èëè çàÿâêó (äî 10 ìá)